In order to solve a long outstanding issue with the old codebase, I re-designed the software using current tools (XTC 14.3.3) and the most recent UAC2 reference codebase. This is a XS2-L2A device.
I'm attempting to build a DFU upgrade image that is compatible with the factory image on the customers' units.
xflash --upgrade 1 app.xe --factory-version 11 -o upgrade.binmakes this error message:
Error: F03118 Tools 12 compatible routing id's and routing tables must be specified in upgrade XN
I also tried using the --factory option to specify a factory image that was built with XDW 11.11.1:
xflash --upgrade 1 app.xe --factory fi.xe -o upgrade.binmakes this error message:
target-xn-v0-b83b8d07: Error: XN11192 Incomplete network configuration (no direction specified for link "4" on node "0")
These errors are cryptic to me. Can I get some guidance for a successful upgrade build?
I've successfully used the --factory-version switch in the past (for a different product) to build an upgrade with XTC13 tools that is compatible with XTC12-built factory image. That was for a L1 device.
It seems that there is a problem with the --factory-image switch, perhaps related to booting the multi-tile device?
thanks